Services: Commercial Alterations
BarrierEnergy is your one-stop-shop for consulting, referrals, and assessments for your commercial alterations project. We will help you stay on schedule, on budget, and compliant with energy standards.
Title 24 Compliance
Title 24 of the California Energy Commission (CEC) outlines energy efficiency standards for new, altered, and existing buildings in the state of California. The HERS index gives buildings a scoring based on their energy efficiency, out of a 0-150 scale. California requires a mandatory energy score, as well as mandatory compliance measures. Optional upgrades and tests can translate into compliance points. For more information, visit the CEC website.
HERS Raters
The Home Energy Rating System (HERS) is used to test and enforce energy code standards set by the California Energy Commission. HERS Raters are private building inspectors who perform state compliance inspections and functional tests on residential and commercial buildings. A HERS Rater is licensed to collect and measure data on every energy consuming system in a building order to calculate an accurate energy scoring. At BarrierEnergy, our certified HERS Raters are thoroughly trained on all new building codes and regulations.
Our Services
Recently, a new code cycle for building compliance in California was set as of 2019. In 2020, these standards go into effect. Our team offers over a decade of experience to help you keep up in a constantly changing work environment. BarrierEnergy’s goal is to keep your construction project progressing smoothly. Furthermore, we can help you to decide what solutions will work best for your project and budget by collaborating between the projects’ architects, builders, contractors, and owners. Contact us to discuss your energy solution, assessment, and HERS rating needs.
Commercial Alterations
Commercial projects that fall under Title 24 commercial codes include multi-family dwelling units, storefronts, offices, and any common indoor space that is non-residential. Alterations consist of additions, remodels, and change-outs and energy efficiency upgrades. A change-out is when someone replaces a component of the HVAC system, such as the ductwork or the furnace. Any of these alterations require a HERS test by California state law. The technician must certify that the installation has remained within energy efficiency guidelines.
NRCC
E-Project Management
More Info
BarrierEnergy will take care of the paperwork and data entry for your project, from beginning to end!
Pre-HERS / Existing Conditions
More Info
Pre-HERS is an investment in your project and hopes clients save thousands. After reporting the existing conditions to authorities, we will help you assess your budget to decide which upgrades will benefit you the most.
This preliminary measure will prevent any time delay down the road, and make sure your entire project runs smoothly. To learn more visit our blog post on Existing Conditions Reports.
Consulting / Planning
More Info
Projects go more smoothly when the architect, HERS Rater, and T-24 consultant discuss the project from beginning to end. We will offer consultation to help you stay on schedule, on budget, and compliant with energy standards. The advice we offer includes Q&A, compliance measures, brand selection, and referrals. Click here to learn more about what consultation adds to your project.
The design plan is the foundation of your construction project. Our team will review your plan set to maximize the energy performance of your property. We will take on translating your plans into a Report, which shows an overview of all energy-consuming features.
Kitchen Hood
More Info
It’s important to keep the kitchen cool and the cooking area clean (free of airborne bacteria). Airflow requirements must be taken into account during construction.
As you are designing your kitchen, an expert will approve its compliance with efficiency standards. Read more on our page for kitchen hood testing.
Air Balance
More Info
Air balance refers to the even distribution of airflow throughout a building. When new ductwork or HVAC systems are installed, duct vents will be tested to certify consistent airflow in each room and level. Keep this in mind when designing your HVAC system.
Read more on our page for Air Balance Testing.
Electrical Power Distribution System
More Info
So, the goal is to deisgn an efficient, yet cost effective Power Distribution System. We are the experts that will help you do just that, while adhering to California State efficiency requirements.
Fenestration Approach (Doors & Windows)
More Info
Factors of thermal transmission include placement, reflectiveness, tinting, etc. Therefore, different kinds of windows and doors are required depending on the setting. We will consult you on which windows will fit best with your project while filling out all necessary documentation. Learn more about selecting the correct windows and doors here.
HVAC
More Info
We are here to make sure your project meets these requirements as set by Title 24. In addition, we will offer our recommendations of what materials and components to use for the best possible system design.
At BarrierEnergy, we understand all these calculations can be complicated time-consuming. We want to maximize your energy savings by offering you the expert advice you need. That’s why we’re dedicated to walking you through these processes. Reach out to one of our experts today.
Solar Ready Area
More Info
Currently, all new or altered buildings in the state of California must have sufficient space for solar panel installation. A Solar Ready Area is a large, relatively flat empty space on the roof, which could potentially hold solar panels.
This law was created as a precursor for PV solar requirements. Most new buildings will need to have solar panels installed unless they meet certain exemptions. Learn more on our page about Solar Ready Area and Solar Panels.
Lighting
More Info
In order to meet efficiency guidelines, lighting systems must adhere to a specific “power allowance”. Using energy-efficient bulbs, such as LED, will allow you to stay within the allotted allowance. Another method of limiting waste is to install lighting controls such as movement detecting lights, automatic shut-off schedules, and so on. Learn more about Title 24 Lighting.
Commercial Refrigeration
More Info
Hot Water Systems
More Info
The minimum efficiency regulations for water heating systems are determined by the California Energy Commission. Commercial buildings may have multiple water heaters, storage tanks, and heater systems. Learning the calculations and codes can be complicated and time-consuming. That’s why we have a team of certified experts who are trained to take care of all the legwork. We know efficiency codes in and out!
Learn more about compliance credits on our page on efficient water heaters.
Garage Exhaust
More Info
In addition to ventilation system acceptance testing, garages are also required to maintain proper air pressure and carbon dioxide sensors. Reach out to an expert at BarrierEnergy today. We will fill out and submit all necessary paperwork from the California Energy Commission.
Fan Power Consumptions
More Info
At BarrierEnergy, our certified HERS Raters are certifieid to calculate these complex equations. That way, your project will pass the compliance phase.
Elevators & Moving Walkways
More Info
Here is yet another form the California Energy Commission wants filled out properly and signed by a field technician. This is because the state must monitor and approve your building plans. A HERS Rater is licensed to calculate these variables. If your commercial project includes moving walkways, you can trust our team to guide you through energy code standards.
Process Boilers
More Info
The process boilers compliance document contains a record of the equipment’s specific description. It must be filled out and approved by a licenesed technician in mathematical detail.
Mechanical Systems
More Info
Cool Roof (Solar Reflective Index)
More Info
California requires a minimum SRI (solar reflective index) value for all new roofs. This standardized measurement makes it possible to calculate and regulate thermal waste. Together, we can ensure your roofing design is in compliance with California energy codes.
Envelope (Exterior) Approach
More Info
NRCI
Electrical Power Distribution
More Info
We are the experts that will help you do just that, while adhering to California State efficiency requirements.
Envelope Sealing / Building Leakage
More Info
All parties responsible in the construction process must sign off on this document to authenticate proper installation. They must visually inspect for gaps or cracks.
To learn more, visit our page on building leakage.
Lighting
More Info
In order to meet energy efficiency guidelines, lighting systems must adhere to a specific “power allowance”. Using energy-efficient bulbs, such as LED, will allow you to stay within the allotted allowance. Another method of limiting waste is to install lighting controls such as movement detecting lights, automatic shut-off schedules, and so on.
This stage is to verify that the plan-set for lighting matches the installation. Learn more about Title 24 Lighting.
Plumbing
More Info
Hot Water Systems
More Info
Hot water systems must be inspected to ensure they were installed according to the plan set. We fill out the plumbing installer verification form and other compliance documentation if water heating credits were claimed in your plans. Learn more about compliance credits on our page on efficient water heaters.
PV Solar
More Info
Title 24 guidelines determine the requirements for solar in your project. Commercial projects under three stories high must have solar panels installed. In the 2022 code, this also carries over to high-rise structures. Learn more about solar regulations and exemptions.
NRCA
Envelope Leakage Testing / Building Air Leakage
More Info
A duct blower is used to determine how much air leakage is coming from a building. This machine does so by gauging air pressure. If the testing results do not meet efficiency standards, identitified leakage paths must be be sealed properly. Boundaries must be visually inspected for gaps. In some cases a smoke test will be performed to determine leakage points.
To learn more, visit our page on building leakage.
Duct Leakage Testing
More Info
As HERS Raters, this test is our specialty! For more information, visit our duct leakage testing page.
Kitchen Hood Testing
More Info
Air Balance Testing
More Info
Valve Leakage Testing
More Info
Doors & Windows
More Info
Learn more about the codes for windows and doors here.
Lighting
More Info
After lighting installations have been verified, a technician must perform acceptance testing. These are functional tests, for the actual performance of the lighting system. Lighting systems should function according to the acceptance documents. Learn more about Title 24 Lighting.
Outdoor Airflow
More Info
At this stage, a field technician will be verifying the functionality of the outdoor air systems including supply fans, heat pumps and ductwork. Other compliance criteria consists of correct thermostat placement and programming, and so on.
Indoor Airflow
More Info
It is our job to verify the return vent has been installed properly and the airflow levels match current standards. Certified HERS Raters will hook a flow hood up to the return vent in order to read its airflow in cubic ft per minute. They will also test the return vents’ air economizer controls, demand control ventilation, and fan variable flow controls.
AC Systems
More Info
Energy Management Systems
More Info
The purpose of acceptance testing is to confirm the EMCS is operating correctly, in concession with energy efficiency standards.
Garage Exhaust
More Info
In addition to ventilation system acceptance testing, garages are also required to maintain proper air pressure and carbon dioxide sensors. Reach out to an expert at BarrierEnergy today. We will fill out and submit all necessary paperwork from the California Energy Commission.
Elevators & Moving Walkways
More Info
In addition, elevators are closed spaces and must have proper lighting and ventilation. A HERS Rater is licensed to verify airflow and lighting efficiency. If your commercial project includes moving walkways, you can trust our team to take care of your acceptance needs.
Refrigerated Warehouses
More Info
HVAC
More Info
The HVAC system must be tested to confirm it functions according to the approved plan-set.
At BarrierEnergy, we understand all these calculations can be complicated time-consuming. We want tyour construction project to progress smoothly. That’s why we’re dedicated to walking you through these processes. Reach out to one of our experts today.
NRCV
Project Status Report
More Info
Duct Leakage Diagnostic Test
More Info
Envelope (Exterior Leakage) Diagnostic Test
More Info
At final, building enclosures will be tested and verified. Any problems that were uncovered in the initial testing phase must be corrected by this point. Our technicians will make a final compliance statement to diagnose the efficiency of the building envelope.
Hot Water System Distribution
More Info
The project will pass or fail the final verification status, based on the energy efficiency requirements of the state. If you have followed the guidance of our team up to this point, you should pass with flying colors!
Mechanical Exhaust
More Info
More Services
LEED Certification
More Info
Through LEED you can also aquire points and credits for your project. We will help you choose which credits to pursue for the most payback. The amount of points obtained will determine which level of certification you are rewarded: Certified, Silver, Gold or Platinum.
Energy Star Certification
More Info
Buildings with the Energy Star stamp have higher market value while saving time and resources in the long run. It’s a great return on investment.
Energy Efficiency Audit
More Info
We are licensed by ASHRAE to perform energy efficiency audits. A licensed technician will analyze all features of the building for efficiency. An energy audit provides an opportunity to assess what improvements could be made to make the building more efficient.
Not only will money and resources be saved, but creature comfort will improve. We recommend this test be performed every year. This will identify and prevent major expenses, such as overworked HVAC systems that cause system collapse.
Energy Efficient Mortgage (EEM)
More Info
Energy Efficient Mortgages can also be used for upgrading new homes. In this instance, HERS Raters would be conducting a home energy assessment to help determine the cost effectiveness of upgrades. The expected savings from installing efficiency upgrades will offset the cost of the improvements. Based on these findings, the FHA approves an allocated amount towards energy efficient upgrades. Therefore, the FHA can guarantee an energy package loan to cover initial installation fees by lumping it in with the mortgage. Reach out to our experts for more information about this service.
PACE Loan / Special Programs
More Info
We know which programs will work best for you. Reach out to our experts today.
Energy Efficient Tax Credits
More Info
For example, 45L is a tax credit that encourages the construction of energy efficient residential properties. Contractors may be eligible for a $2,000 tax credit per energy efficient unit. In order to qualify, a certified field technician must verify the efficiency of the dwelling unit(s) meets the programs standards.
To learn more about the special programs and savings you could qualify for, reach out to our expert team today.
Warranty Sign-Off
More Info
Home Inspection
More Info
During a home inspection, the inspector will document every part of the home. The data they collect will be supported with picture evidence, and documented through an inpection report.
Miscellaneous Compliance Testing
More Info
Our technicians will work with the owner and builders to make sure every step of the construction process is done properly, given codes in certain municipalities.
Basic Health and Safety
More Info
If you are experiencing symptoms of sickness for no apparent reason, it may be a good idea to get some general tests done. We can ensure proper airflow, temperature control, and exterior seal. Reach out to an expert at BarrierEnergy; we are here to protect your health.